• MSD Standard Drawings

    Drawings in the table below are Adobe PDF files.

    For reference, you may also download all MSD Standard Drawings in a single file.

    DRAWING NAME ACCESSION NUMBER (.pdf)
    Standard Drop Manholes
    Standard Precast Concrete Drop Manhole
    Typical Inverts
    Standard Castings for Manholes
    Standard Casting Manhole Frame - Type "A"
    Standard Lamp Hole
    Standard Interceptor Inlet Frame
    Standard Interceptor Inlet Grating
    Structural Dimensions and Steel Details for Reinforced Junction Chambers
    Standard Concrete Collars on Conduits
    Control Dimensions for Typical Trenches for Conduits
    Typical Building Sewers and Stacks
    Standard Manholes on Sanitary Conduits 42" and Under (Type "S")
    Standard Key Block
    Standard Manhole on Sanitary Conduits - 48" and Over (Type "T")
    Standard Precast Concrete Manhole Tee (Type "T" Alternate)
    Standard Concrete Cradle and Encasement
    Standard Temporary Manhole Cover
    Standard Manhole for Sanitary Conduits on Steep Slopes
    Modified Type "T" Manholes
    Modified Type "S" Manholes
    Locking Lid Manhole
    Watertight Lid
    Special Detail for Laying Two Building Sewers in One Trench
    Standard Connection to Existing Brick Sewer
    Standard Batter Board
    Alternate Batter Board
    Self Sealing Manhole Lid
    Standard Precast Concrete Manhole Base
    Typical Encasement for Existing Sanitary Pipe
    Sanitary Manhole Adjustment Using Brick and Mortar Prior to Machine Paving
    Sanitary Manhole Adjustment with Precast Concrete Ring and Mortar Prior to Machine Paving
    Standard Type "A" Sampling and Gauging Manhole
    Standard Type "B" Sampling and Gauging Manhole
    Standard Type "C" Sampling and Gauging Manhole
    Standard Type "D" Sampling and Gauging Manhole
    Standard Type "E" Sampling and Gauging Manhole
    Typical Installation of Building Sewer Lateral
    Standard Inside Drop Manhole
    Standard Grit Chamber
    Low Pressure Force Main Typical Receiving Manhole
    Standard Separation Manhole
    Standard Monitoring Manhole
    Standard Building Connection to a Low Pressure Force Main
    Standard Symbols
    Standard Symbols
    Standard Symbols
    Standard Symbols
    Standard Symbols
    Standard Manhole Cover on Elevated Cones
    Standard Watertight Manhole Cover on Elevated Cones
    Standard Grease Interceptor
    Unreinforced Concrete Cap
    Standard Two Way Cleanout for Building Sewers
    Standard Castings over Two-Way Cleanout
    Standard Lid on Private Sewers
    Standard Watertight Lid on Private Sewers

    Questions or Comments?

    Contact Us

    Report a Sewer Backup:
    (513) 352-4900 24/7 or online

    Customer Call Center:
    (513) 352-4900 24/7

    Project Customer Service:
    (513) 557-3594

    Development Services:
    (513) 244-1330

    Media Inquiries:
    (513) 557-7095

    Email:
    MSD.Communications@cincinnati-oh.gov

    MSD Mailing Address:
    1600 Gest St.
    Cincinnati, Ohio 45204

    MSD Facilities and Directions

    Downloads

    MSD Standard Drawings Package
    (contained in single 3.2 MB PDF)